SH Power provides customized design services according to different voltage levels and environmental conditions. Our technical experts offer comprehensive support—from insulation performance analysis and installation guidance to operation and maintenance advice—ensuring optimal performance under complex operating conditions.
Model | Rated Voltage(kV) | Specified Mechanica Load(kN) | Mark of Connection | Structure height(mm) | Insulation Distance(mm) | Creepage Distance(mm) | Lightning Impulse Withstand Volage | 1 Min Power Requency Wet Withstand Voltage |
FXBW-35/70 | 35 | 70 | 16 | 670 | 480 | 1015 | 230 | 95 |
FXBW-35/120(100) | 35 | 120(100) | 16 | 670 | 450 | 1015 | 230 | 95 |
Through material innovation and structural optimization, composite insulators achieve an optimal balance of high strength, lightweight design, and long service life. Offering high cost-effectiveness, they are critical components in modern power systems for enhancing line safety and are widely used in transmission lines and substations.
Our composite insulators are extensively used in 1000kv,±800kV and other UHV DC and AC transmission projects, providing reliable insulation for critical national power arteries.
Composite post insulators serve as the external-insulation support components for all kinds of equipment in converter stations and substations, providing both electrical insulation and structural support for busbars and electrical apparatus.
Widely applied to support reactors and capacitors in DC and AC filter fields, which are crucial for maintaining power quality in the grid.
Used as integral insulation components for various high-voltage equipment, including circuit breakers, disconnectors, and arresters.
Through material innovation and structural optimization, composite insulators achieve an optimal balance of high strength, lightweight design, and long service life. Offering high cost-effectiveness, they are critical components in modern power systems for enhancing line safety and are widely used in transmission lines and substations.
Our composite insulators are extensively used in 1000kv,±800kV and other UHV DC and AC transmission projects, providing reliable insulation for critical national power arteries.
Composite post insulators serve as the external-insulation support components for all kinds of equipment in converter stations and substations, providing both electrical insulation and structural support for busbars and electrical apparatus.
Widely applied to support reactors and capacitors in DC and AC filter fields, which are crucial for maintaining power quality in the grid.
Used as integral insulation components for various high-voltage equipment, including circuit breakers, disconnectors, and arresters.