SH Power offers full life-cycle support for its transformers,covering solution design, model optimization, and on-site commissioning—all handled by our experienced technical team. We provide tailor-made solutions for various applications to ensure efficient operation and maximize energy savings.
The SCB series 35kV excitation-free voltage regulating dry-type transformers manufactured by our company are products of low loss, conforming to requirements of GB/T1094.11, GB/T10228 and IEC60076.11. These products have the following characteristics: Technical Parameters | |||||||||||||||||||
| SC(B)10 200~2500/20 | |||||||||||||||||||
| Primary Voltage(kV): | 20(22, 24) | ||||||||||||||||||
| Secondary Voltage(kV): | 0.4 | ||||||||||||||||||
High-voltage Tapping Range(%): | ±2×2.5% | ||||||||||||||||||
| Connection Symbol: | Dyn11, Yyn0 | ||||||||||||||||||
| Insulation level: | L1 125 AC 50/ L1 AC3 | ||||||||||||||||||
| Model | Impedance Uk(%) | No-load Loss Po(w) | Load Loss(120ºC)pk(w) | No-load Current lo(%) | Sound Pressure level Lpa(AN) dB |
| SC(B)10-200/20 | 6 | 655 | 2490 | 1.4 | 47 |
| SC(B)10-250/20 | 6 | 775 | 3420 | 1.2 | 47 |
| SC(B)10-315/20 | 6 | 870 | 4080 | 1.2 | 48 |
| SC(B)10-400/20 | 6 | 1030 | 4840 | 1.0 | 48 |
| SC(B)10-500/20 | 6 | 1210 | 5790 | 1.0 | 50 |
| SC(B)10-630/20 | 6 | 1370 | 6840 | 0.9 | 50 |
| SC(B)10-800/20 | 6 | 1570 | 8260 | 0.9 | 51 |
| SC(B)10-1000/20 | 6 | 1860 | 9780 | 0.8 | 52 |
| SC(B)10-1250/20 | 6 | 2140 | 11500 | 0.8 | 52 |
| SC(B)10-1600/20 | 6 | 2150 | 13800 | 0.8 | 53 |
| SC(B)10-2000/20 | 6 | 2190 | 16300 | 0.6 | 53 |
| SC(B)10-2500/20 | 6 | 2480 | 19300 | 0.6 | 54 |
| SC11 800~25000/35 | |||||||||||||||||||
| Primary Voltage(kV): | 35(33, 36.5, 37.5, 38.5) | ||||||||||||||||||
| Secondary Voltage(kV): | 0.4, 0.48 ,0.55, 0.63, 0.69, 0.8, 1.14, 3.15, 6.0, 6.3, 10.5 | ||||||||||||||||||
High-voltage Tapping Range(%): | ±2×2.5% | ||||||||||||||||||
| Connection Symbol | Yd11, YNdl1, Dyn11 | ||||||||||||||||||
| Model | Impedance Uk(%) | No-load Loss Po(w) | Load Loss(120ºC)pk(w) | Sound Pressure Level Lpa(AN) dB |
| SC11-800/35 | 6 | 2020 | 9400 | 0.85 |
| SC11-1000/35 | 6 | 2400 | 10900 | 0.85 |
| SC11-1250/35 | 6 | 2810 | 12900 | 0.75 |
| SC11-1600/35 | 6 | 3320 | 15400 | 0.75 |
| SC11-2000/35 | 7 | 3800 | 18200 | 0.65 |
| SC11-2500/35 | 7 | 4370 | 21800 | 0.65 |
| SC11-3150/35 | 8 | 5425 | 24500 | 0.65 |
| SC11-4000/35 | 8 | 6310 | 29400 | 0.6 |
| SC11-5000/35 | 8 | 7530 | 34900 | 0.55 |
| SC11-6300/35 | 8 | 8910 | 40800 | 0.55 |
| SC11-8000/35 | 9 | 10100 | 46000 | 0.45 |
| SC11-10000/35 | 9 | 11600 | 55500 | 0.45 |
| SC11-12500/35 | 9 | 14100 | 64600 | 0.35 |
| SC11-16000/35 | 9 | 17300 | 76000 | 0.35 |
| SC11-20000/35 | 10 | 20660 | 85500 | 0.3 |
| SC11-25000/35 | 10 | 24300 | 101000 | 0.3 |
Product functions
Including oil-immersed, dry-type and packaged substation transformers to cover all voltage levels and application needs.
Built with high-grade grain-oriented silicon steel and premium insulation systems for low no-load and load losses and outstanding energy savings.
Oil-immersed and packaged units offer superior moisture-proof, leak-proof and dielectric performance, guaranteeing long-term stability.
The entire process strictly follows national standards and ISO 9001 quality management system.
Custom designs are available to match specific site conditions and load characteristics.
Robust construction incorporates overload and high-temperature protection functions.
Compliant with RoHS and other environmental regulations—low noise, minimal losses.
Our 110kV and 220kV power transformers are widely used in power plants and transmission substations for efficient voltage transformation.
We provide specialized solutions, including inverter and step-up integrated transformers, for renewable energy projects like solar farms and wind power plants.
Our dry-type and pad-mounted transformers are perfect for industrial facilities, commercial complexes, data centers, and high-rise buildings, providing safe and reliable power distribution.
Our distribution transformers, including pole-mounted and pad-mounted types, are essential for urban and rural power grids, delivering electricity to homes and public facilities.